List of PowerEdge servers
Rack-mounted 11th-generation PowerEdge servers
PowerEdge is a server line by Dell , following the naming convention for other Dell products: PowerVault (data storage) and PowerConnect (data transfer & switches).
Below is an overview of current and former servers within Dell's PowerEdge product line. Different models are or were available as towers, 19-inch racks or blades . In the current naming scheme, towers are designated by T , racks by R , and blades by M (for modular).[ 1] The 19″ rack-servers come in different physical heights expressed in rack units or U . Most modern servers are either 1U or 2U high while in the past the 4U was more common.
Model naming
Over the years, many different types of PowerEdge servers have been introduced and there was wide variety of product and family codes used within the PowerEdge name.
Itanium servers
The Dell Itanium-based servers were introduced before this new naming-convention was introduced and were only available as rack servers.
New naming conventions
Three digits
Since the introduction of the Generation 10 servers in 2007 Dell has adopted a standardized method for naming their servers; the name of each server is now represented by a letter followed by 3 digits.[ 2] The letter indicates the type of server: R (for Rack-mountable) indicates a 19″ rack-mountable server, M (for Modular) indicates a blade server, whilst T (for Tower) indicates a stand-alone server.[ 3]
This letter is then followed by three digits.
The first digit refers to the number of sockets in the system: 1 to 3 for one socket, 4 to 7 for two sockets, and 8 or 9 for four sockets.
The middle digit refers to the generation: 0 for Generation 10, 1 for Generation 11, and so on.
The third digit indicates the make of the CPU: 0 for Intel or 5 for AMD .
For example: The Dell PowerEdge M610 is a two-socket blade server of the 11th generation using an Intel CPU. Whereas the R605 is a two-socket, 10th generation AMD-based rack-server.
Four digits
For four-digit naming convention:
The first digit after the letter indicates the class of the system, with 1 –5 defaulting to iDRAC Basic and 6 –9 defaulting to iDRAC Express.
The second digit indicates the generation, with 0 for 10th generation, 1 for 11th generation and so on.
The third digit indicates the number of CPU sockets, 1 for one socket and 2 for two sockets.
The fourth digit indicates the make of the CPU, 0 for Intel and 5 for AMD.
For example: The Dell PowerEdge R6415 model is a rack, mid-range, 14th generation, single CPU socket system with AMD Processor.
[ 1]
Blade servers
Since Generation 10 , there are models for the M1000e enclosure. The blade-servers in Generation 8 and Generation 9 are using another enclosure that is not compatible with the current M1000e system. In form-factor there are two models: half-height and full-height.
In an enclosure you can fit 8 full or 16 half-height blades (or a mix). Each server has two or four on-board NIC's and two additional Mezzanine card -slots for additional I/O options: 1 Gb or 10 Gb Ethernet cards, Fibre Channel HBA 's or InfiniBand slots. Apart from USB connectors a blade-server doesn't offer direct connections: all I/O goes via the midplane of the enclosure.
Early systems
Early systems (SP, XE, EL, XL lines)
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
SP 433
Tower
1
Intel 80486DX 33 MHz (P4)
EISA/PCI
SP 450
Tower
1
Intel 80486DX2 50 MHz (P24)
EISA/PCI
SP 466
Tower
1
Intel 80486DX2 66 MHz (P24)
EISA/PCI
SP 560
Tower
1 Socket 4
Pentium 60 60 MHz (P5)
EISA/PCI
SP 566
Tower
1 Socket 4
Pentium 66 66 MHz (P5)
EISA/PCI
SP 575-2
Tower
1995[ 4]
1,2 Socket 5
Pentium 75 75 MHz (P54C)
EISA/PCI
SP 590
Tower
1994[ 5]
1 Socket 5
Pentium 90 90 MHz (P54C)
192 MB
SIMM
8
EISA/PCI
SP 590-2
Tower
1,2 Socket 5
Pentium 90 90 MHz (P54C)
EISA/PCI
SP 5100[ 6]
Tower
1,2
Pentium 100 100 MHz (P54C)
EISA/PCI
SP 5100-2[ 6]
Tower
1,2
Pentium 100 100 MHz (P54C)
EISA/PCI
SP 5133[ 6]
Tower
1,2
Pentium 133 133 MHz (P54CS)
EISA/PCI
SP 5133-2[ 6]
Tower
1,2
Pentium 133 133 MHz (P54CS)
EISA/PCI
SP 5166[ 6]
Tower
1,2
Pentium 166 166 MHz (P54CS)
EISA/PCI
SP 5166-2[ 6]
Tower
1,2
Pentium 166 166 MHz (P54CS)
EISA/PCI
XE 433
Tower
1
Intel 80486DX 33 MHz (P4)
EISA/PCI
XE 450
Tower
1
Intel 80486DX2 50 MHz (P24)
EISA/PCI
XE 466
Tower
1
Intel 80486DX2 66 MHz (P24)
EISA/PCI
XE 560
Tower
1 Socket 4
Pentium 60 60 MHz (P5)
EISA/PCI
XE 566
Tower
1 Socket 4
Pentium 66 66 MHz (P5)
EISA/PCI
XE 575-2
Tower
1,2 Socket 5
Pentium 75 75 MHz (P54C)
EISA/PCI
XE 590
Tower
1,2 Socket 5
Pentium 90 90 MHz (P54C)
EISA/PCI
XE 590-2
Tower
1,2 Socket 5
Pentium 90 90 MHz (P54C)
EISA/PCI
XE 5100
Tower
1,2
Pentium 100 100 MHz (P54C)
EISA/PCI
XE 5100-2
Tower
1,2
Pentium 100 100 MHz (P54C)
EISA/PCI
XE 5133
Tower
1,2
Pentium 133 133 MHz (P54CS)
EISA/PCI
XE 5133-2
Tower
1,2
Pentium 133 133 MHz (P54CS)
EISA/PCI
XE 5166
Tower
1,2
Pentium 166 166 MHz (P54CS)
EISA/PCI
XE 5166-2
Tower
1,2
Pentium 166 166 MHz (P54CS)
EISA/PCI
EL 575
Tower
Pentium 75 75 MHz (P54C)
ISA/PCI
EL 590
Tower
Pentium 90 90 MHz (P54C)
ISA/PCI
EL 5100
Tower
Pentium 100 100 MHz (P54C)
ISA/PCI
EL 5120
Tower
Pentium 120 120 MHz (P54CQS)
ISA/PCI
EL 5133
Tower
Pentium 133 133 MHz (P54CS)
ISA/PCI
Web Server
Tower
1995[ 7]
Pentium 133 133 MHz (P54CS)
ISA/PCI, based on quad processor EL[ 7]
XL 5133
Tower
1-4 (single, quad capable)
Pentium 133 133 MHz (P54CS)
EISA/PCI
XL 5133-2
Tower
1-4 (dual, quad capable)
Pentium 133 133 MHz (P54CS)
EISA/PCI
XL 5133-4[ 8]
Tower
1-4 (quad)
Pentium 133 133 MHz (P54CS)
EISA/PCI
XL 5166
Tower
1-4 (single, quad capable)
Pentium 166 166 MHz (P54CS)
EISA/PCI
XL 5166-2
Tower
1-4 (dual, quad capable)
Pentium 166 166 MHz (P54CS)
EISA/PCI
XL 5166-4
Tower
1-4 (quad)
Pentium 166 166 MHz (P54CS)
EISA/PCI
Generation 1
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
2100[ 9]
Tower
1996
Intel 440FX
1 Socket 8
Pentium Pro 180 MHz or 200 MHz
256 MB
4, 168-pin DIMM
4100[ 10]
Tower
2 Socket 8
Pentium Pro 180 MHz or 200 MHz
1 GB
8, 168-pin DIMM
6100[ 11]
Tower
4 Socket 8
Pentium Pro 200 MHz
2 GB
16, 72-pin
Generation 2
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
2200[ 12]
Tower
2
Pentium II, 233 - 333 MHz
512 MB
4, ECC
3 full size SCSI drives (screw in)
4200[ 13]
Tower
Intel 440FX
2
Pentium II 233, 266, 300, or 333 MHz
512 MB
8, 168-pin EDO DIMM
Generation 3
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
350[ 14]
1U Rack
circa 2001
Intel 440BX
Pentium III 650Mhz-1.0 GHz or Celeron 600+
1 GB
4, SDRAM unbuffered and registered PC-100
(2) int. 3.5 ATA-100 (1) slim 3.5″ floppy (1) slim CD-ROM
(2) Intel 82559 10/100 125 W 898 BTU/hr (max)
1300[ 15]
Tower
Intel 440BX
1
Pentium II at 350, 400, or 450 MHz
1 GB
unbuffered, 72-bit SDRAM or registered, 72-bit SDRAM
2300[ 16]
Tower
1998
Intel 440BX
2
Pentium II 333, 350, 400, 450 MHz
1 GB
4, unregistered PC-100 SDRAM
6 Ultra2 SCSI HDD bays
4300[ 17]
7U Rack
Intel 440GX
2
Pentium II 350, 400, or 450 MHz
1 GB
4, 168-pin unbuffered DIMMs or registered DIMMs
8 SCSI bays
4350[ 18]
Rack
Intel 440GX
2
Pentium II 350, 400, or 450 MHz
2 GB
6300[ 19]
Tower
4
Pentium II Xeon
4 GB
4, registered EDO DIMM
6 Ultra2 SCSI HDD bays
6350[ 20]
4U Rack
4
Pentium II Xeon at 400 MHz
4 GB
16, registered EDO DIMM
3 HDD bays
Generation 4
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
2400[ 21]
Tower
2000[ 22]
2
Pentium III 500 MHz minimum
2 GB
4, registered PC-133 SDRAM
6 Ultra2 SCSI HDD bays
2450[ 23]
2U Rack
2001
2
Pentium III 600 MHz minimum
2 GB
168-pin registered SDRAM 133-MHz
4400[ 24]
7U Rack or Tower
2
Pentium III Xeon, 600 MHz minimum
4 GB
registered PC133 SDRAM
Up to 10 internal SCSI bays
Introduced circa 1999
6400[ 25]
Tower
4
Pentium III Xeon, 550 MHz minimum
8 GB
16, registered PC-133 SDRAM
6 or 8 Ultra3 SCSI drives
Introduced circa 1999
6450[ 26]
4U Rack
4
Pentium III Xeon 550 MHz
8 GB
16, registered PC-133 SDRAM
4 internal SCSI bays
Introduced circa 1999
8450[ 27]
Rack
2000[ 28]
8
Pentium III Xeon 500 MHz
32 GB
168-pin SDRAM 100 MHz
Generation 5
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
1500SC[ 29]
Tower
2, Socket 370
Pentium III (1.13 GHz-1.4 GHz)
4GB
4, registered PC-133 SDRAM
6 hot-swappable Ultra3 SCSI HDD bays
1550[ 30]
1U Rack
2001[ 31]
ServerWorks HE-SL
2, Socket 370
Pentium III (933 MHz-1.4 GHz)
4GB
4, registered PC-133 SDRAM
3 hot-swappable Ultra3 SCSI HDD bays
2500[ 32]
Tower or 5U Rack
2, Socket 370
Pentium III 933 MHz minimum
4 GB
6, ECC registered PC-133 SDRAM
6 hot-swappable Ultra3 SCSI HDD bays, splittable
2550[ 33]
2U Rack
2, Socket 370
Pentium III 933 MHz minimum
4 GB
registered PC133 SDRAM
5 internal SCSI bays
Introduced circa 2001
Itanium
The Itanium line was a separate 'generation' from the traditional server line, but roughly falls between generations 5 and 6.
Itanium systems (3250, 7150, 7250 models (2001–2004))
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
3250[ 34]
2U Rack
2003
Intel E8870
2 PAC611
Intel Itanium 2 1.5 GHz, 1.3 GHz, 1.4 GHz, 1.0 GHz
16 GB
DDR SDRAM
2 x 1″ SCSI drives
7150[ 35]
7U Rack
2001[ 36]
4 PAC418
Intel Itanium minimum 733 MHz
64 GB
PC100 memory
4 hotplug SCSI bays
7250[ 37]
Rack
2004
Intel E8870
4 PAC611
Intel Itanium 2
32 GB
DDR ECC memory
3 hotplug SCSI bays
Generation 6
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
650[ 38]
1U Rack
2003
1
Pentium 4 up to 3.06 GHz or Celeron up to 1.8 GHz
3 GB
DDR
2× IDE or SCSI
1650[ 39]
1U Rack
2002[ 40]
2
Pentium III 1.13 GHz+
4 GB
4, ECC SDRAM 133
1655 MC[ 41]
3U Blade
2004
ServerWorks ServerSet LE3.0
2 (per Blade)
Pentium III at 1.4 GHz
2 GB (per Blade)
4, ECC SDRAM 133
Houses up to 6 blades
2600[ 42]
Tower or 5U Rack
2004
Intel E7501
2 Socket 604
Xeon III at 2.4 GHz, 2.8 GHz, 3.06 GHz and 3.2 GHz
12 GB
6, ECC DDR 266
6 HDD bays (SCSI)
2650[ 43]
2U Rack
2004
ServerWorks GC-LE
2 Socket 603
Xeon at 2.0 GHz, 2.4 GHz, 2.8 GHz, 3.06 GHz and 3.2 GHz
12 GB
6, ECC DDR 266
5 HDD bays (SCSI)
4600[ 44]
Tower or 6U Rack
2003
ServerWorks GC-HE
2 Socket 603
Xeon at 2.4 GHz, 2.6 GHz, 2.8 GHz to 3.0 GHz
24 GB
ECC DDR
2 RAM riser cards
6600[ 45]
Tower or 7U Rack
2004
ServerWorks GC-HE
4
Xeon MP at 2.0 GHz, 2.2 GHz, 2.7 GHz or 3.0 GHz
32 GB
ECC DDR 266
8 SCSI
4 RAM riser cards
6650[ 45]
4U Rack
2004
ServerWorks GC-HE
4
Xeon MP at 1.4 GHz, 2.0 GHz, 2.2 GHz, 2.7 GHz or 3.0 GHz
32 GB
ECC DDR 266
5 SCSI
4 RAM riser cards
Generation 7
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
700[ 46]
Tower
2004
Intel E7210
1 Socket 478
Pentium 4(up to 3.2 GHz/800 MHz) or Celeron (2.4 GHz)
4 GB
DDR 400
4 HDD bays
750[ 47]
1U Rack
2005
Intel E7210
1 Socket 478
Pentium 4(up to 3.4 GHz/800 MHz) or Celeron (2.4 GHz)
4 GB
DDR 400
2 SCSI or SATA
1750[ 48]
1U Rack
2004
ServerWorks GC LE
2 Socket 604
Xeon up to 3.2 GHz
8 GB
4, DDR 266
3 HDD bays (SCSI)
Generation 8
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
800[ 49]
Tower
2005
Intel E7221
1 LGA 775
Pentium 4 up to 3.8 GHz or Celeron up to 2.53 GHz
4 GB
4, ECC DDR2 400/533
4 × 1″ SCSI or SATA
830[ 50]
Tower
2005
Intel E7230
1 LGA 775
Pentium D up to 3.2 GHz or Pentium 4 up to 3.6 GHz or Celeron D 2.53 GHz
8 GB
4, ECC DDR2 533-667
4 × HDD bays
840 (Gen I, II) [ 51] [ 52]
Tower
2006
Intel 3000
1 LGA 775
Xeon X3200 (Gen II only), Xeon 3000, Pentium or Celeron
8 GB
4, ECC DDR2 533-667
2 × 5.25″ ext. 1 × 3.5″ ext. 4 × 3.5″ int. 4 SATA 2 IDE
1800[ 53]
Tower or 5U Rack
Intel E7520
2 Socket 604
Xeon, 800 MHz FSB
12 GB
6, ECC DDR2
6 × HDD bays (SCSI)
1850[ 54]
1U Rack
2005
Intel E7520
2 Socket 604
Xeon, 800 MHz FSB
16 GB
6, ECC DDR2 400
2 × HDD bays (SCSI)
1855[ 55]
Blade
2005
Intel E7520
2 Socket 604
Xeon, 800 MHz FSB
12 GB
6, ECC DDR2
2 × HDD bays per blade (SCSI)
Uses same blade chassis as 1955, up to 10 blades
2800[ 56]
Tower or 5U Rack
2005
Intel E7520
2 Socket 604
Xeon Single or Dual-core
16 GB
6, DDR2 400
8 to 10 HDD bays (SCSI)
2850[ 57]
2U Rack
2005
Intel E7520
2 Socket 604
Xeon up to 3.8 GHz or Dual-core Xeon at 2.8 GHz
16 GB
6, DDR2 400
6 × HDD bays (SCSI)
6800[ 58]
Tower
2006
Intel 8501
4 Socket 604
Xeon 7100
64 GB
16*, ECC DDR2
10 Hotplug SCSI bays
RAM slots only with daughterboard
6850[ 59]
4U Rack
2006
Intel 8501
4 Socket 604
Xeon 7100
64 GB
16*, ECC DDR2
5 Hotplug SCSI bays
RAM slots only with daughterboard
Generation 9
Model
Chassis
Year
Chipset
CPU Sockets
CPU
RAM (Max)
RAM (Type)
Drive bays
Comments
850[ 60]
1U Rack
2005
Intel E7230
1 LGA 775
Intel Pentium 4 (up to 3.8 GHz) or Celeron (2.53 GHz) or Pentium D dual-core (up to 3.2 GHz)
8 GB
4, ECC DDR2 533/667 MHz
2 × 3.5″ SATA or SCSI
860 (Gen I, II) [ 61] [ 62]
1U Rack
2006
Intel 3000
1 LGA 775
Celeron D , Pentium D 925 , Celeron 430/440 , Pentium Dual-Core E2160 , Core 2 Duo E4400 , Xeon 3000 , Xeon 3200
8 GB
4, ECC DDR2 533/667 MHz
2 × 3.5″ SATA or SAS and 1 × slim optical
The PE 850 and 860 share chassis with the R200, and other than name badge are visually identical.
1900[ 63]
Tower
2006
Intel 5000P
2 LGA 771
Xeon 5000 , 5100 or 5300
16 GB
8, DDR2 533/667 MHz FB-DIMM
6 × 3.5″ SAS/SATA and 1 × Peripheral bay and 1 × 3.5″ floppy
This model replaces the 1800. Peripheral bay can hold 2 × 5.25″ devices
1950 (Gen I, II, III) [ 64]
1U Rack
2006
Intel 5000X
2 LGA 771
GI: Xeon 5000, 5100 GII: Xeon 5000, 5100, 5300 GIII: Xeon 5000, 5100, 5200 , 5300, 5400
GI & GII: 32 GB; GIII: 64 GB
GI & GII: 8, ECC DDR2 533/667 MHz FB-DIMM GIII: 8, ECC DDR2 667 MHz FB-DIMM
2 × 3.5″ SAS/SATA or 4 × 2.5″ SAS and 1 × slim optical
1955[ 65]
Blade
2006
Intel 5000P
2 LGA 771
Xeon 5000, 5100 or 5300
32 GB
8, ECC DDR2 FB-DIMM
2 × 2.5″ SAS/SATA
Uses same blade chassis as 1855. Up to 10 blades
2900 (Gen I, II, III) [ 66]
Tower or 5U
2006
Intel 5000X
2 LGA 771
Xeon 5000, 5100, 5300 or 5400
48 GB
12, ECC DDR2 533/667 MHz FB-DIMM
8 × 3.5″ SAS/SATA and 1 × Flexbay and 1 × Peripheral bay and 1 × 3.5″ floppy
Flexbay can hold 2 × 3.5″ HDD. Peripheral bay can hold 2 × 5.25″ devices
2950 (Gen I, II, III) [ 67] [ 68]
2U Rack
2006
Intel 5000X
2 LGA 771
GI: Xeon 5000, 5100 GII: Xeon 5000, 5100, 5300 GIII: Xeon 5000, 5100, 5200, 5300, 5400
GI: 32 GB; GII[ 69] & GIII: 64 GB
GI & GII: 8, ECC DDR2 533/667 MHz FB-DIMM GIII: 8, ECC DDR2 667 MHz FB-DIMM
8 × 2.5″ SAS and 1 × Peripheral bay or 4 × 3.5″ SAS/SATA and 1 × Peripheral bay or 6 × 3.5″ SAS/SATA and 1 × slim optical
All configurations include 1 × slim optical drive. Peripheral bay options: Floppy Drive, DAT72 Tape Drive
2970[ 70]
2U Rack
2007[ 71]
Broadcom HT-2100 and HT-1000
2 Socket F
Opteron 2200
32 GB
8, ECC DDR2 667 MHz
8 × 2.5″ SAS/SATA II or 6 × 3.5″ SAS/SATA and 1 × Peripheral bay and 1 × slim optical
Peripheral bay options; Floppy Drive, PowerVault 100T Tape Drive
6950[ 72]
4U Rack
2006[ 73]
Broadcom HT-2100 and HT-1000
4 Socket F
Opteron 8200 or 8300
64 GB
16, ECC DDR2 667 MHz
5 × 3.5″ SAS and 1 × slim optical
Generation 10
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
T100[ 74]
Tower
2008[ 75]
Intel 3200
1 LGA 775
Xeon 3000 , Core 2 Duo 7000, Pentium 2000, Celeron 1200 or Celeron 400
8 GB
4, ECC DDR2 677-800
2 × 3.5″ SATA or SAS and 2 × 5.25″
T105[ 76]
Tower
2008
nVidia CK8-04 Pro
1 Socket AM2
Opteron 1200 , Opteron 1300 , Sempron LE1250
8 GB
4, ECC DDR2 677-800
2 × 3.5″ SATA or SAS and 2 × 5.25"
R200[ 77]
1U Rack
2010
Intel 3200
1 LGA 775
Xeon 3000 , Core 2 Duo, Celeron
8 GB
4, ECC DDR2 667-800 SDRAM[ a]
2 × 3.5″ non-hot-swap SATA or SAS and 1 × 5.25″ removable CD/DVD
T300[ 78]
Tower
2007
Intel 5100
1 LGA 771
Xeon 5000 , Xeon 3000 , Core 2 Duo, Celeron
24 GB
6, ECC DDR2 667
4 × 3.5″ SATA or SAS
R300[ 79]
1U Rack
Intel 3400
1 LGA 771
Xeon 5000 , Xeon 3000 , Core 2 Duo, Celeron
24 GB
6, ECC DDR2 667
2 × 3.5″
M600[ 80]
Blade
Intel 5000P
2 LGA 771
Xeon 5000
64 GB
8, ECC DDR2 667
Fits in the M1000E chassis
T605[ 81]
Tower
2008[ 82]
Broadcom HT2100 and HT1000
2 Socket F
Opteron 2000
32 GB
8, ECC DDR2
4 × 3.5″ and 1 × 5.25″
M605[ 83]
Blade
NVIDIA MCP55
2 Socket F
Opteron 2000, 2200 or 2300
64 GB
8, ECC DDR2 800
2 × 2.5″ SAS or SATA
Fits in the M1000E chassis
R805[ 84]
2U Rack
2008[ 85]
NVIDIA MCP55Pro + IO-55
2 Socket F
Opteron 2400
128 GB
16, ECC DDR2
2 × 2.5″ and 1 × slim optical
M805[ 86]
Blade
NVIDIA MCP55
Opteron 2000
128 GB
16, ECC DDR2 667-800
2 × 2.5″ SAS or SSD
Fits in the M1000E chassis
R900[ 87]
4U Rack
Intel 7300
4 Socket 604
Xeon 7200 , 7300 or 7400
256 GB
32, FBD DDR2 667-1333
5 × 3.5″ SAS or 8 × 2.5″ SAS
R905[ 88]
4U Rack
Broadcom HT-2100 and HT-1100
4
Opteron 8000
256 GB
32, ECC DDR2
8 × 2.5″ or 5 × 3.5″
EOL : 7/23/2015
M905[ 89]
Blade
NVIDIA MCP55
4
Opteron 8000
192 GB
24, ECC DDR2 667–800
2 × 2.5″ SAS or SSD
Fits in the M1000E chassis
Generation 11
Released by Dell in 2010
Model
Chassis
Year
Chipset
CPU
(No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
T110[ 90]
Tower
Intel 3420
1 LGA 1156
Xeon 3400 , Celeron G1101 , Pentium G6950 , Core i3-530 or i3-540
16 GB
4, U-DIMMs ECC DDR3 1066-1333
4 × 3.5″ SAS or SATA
T110 II[ 91]
Tower
2011
Intel C202
1 LGA 1155
Xeon E3-1200 or E3-1200 v2, Celeron G400 / G500, Pentium G600 / G800
32 GB
4, U-DIMMs ECC DDR3 1066-1600
4 × 3.5″ or 6 × 2.5″ SAS or SATA
R210[ 92]
1U Rack
Intel 3420
1 LGA 1156
Xeon 3400 , Celeron G1101 , Pentium G6950 or Core i3-500
16 GB
4, U-DIMMs ECC DDR3 1066-1333
2 × 2.5″ or 2 × 3.5″ SAS, SATA or SSD
R210 II[ 93]
1U Rack
2011
Intel C202
1 LGA 1155
Xeon E3-1200 or E3-1200 v2, Celeron G400 / G500, Pentium G600 / G800
32 GB
4, U-DIMMs ECC DDR3 1066-1600
4 × 2.5″ or 2 × 3.5″ SAS, SATA or SSD
T310[ 94]
Tower
Intel 3400
1 LGA 1156
Xeon 3400 , Celeron G1101 , Pentium G6950 or Core i3-500
32 GB
6, R-DIMMs or 4, U-DIMMs, DDR3 800-1333
4 × 3.5″ SAS or SATA
R310[ 95]
1U Rack
Intel 3420
1 LGA 1156
Xeon 3400 , Celeron G1101 , Pentium G6950 , Core i3-530 or i3-540
32 GB
6, 1066–1333
4 × 3.5″ or 4 × 2.5” SAS or SATA
T410[ 96]
Tower
2009[ 97]
Intel 5500
2 LGA 1366
Xeon 5500 or 5600
128 GB
8, DDR3 800-1333
6 × 3.5″ and 2 × 5.25″ SSD, SAS or SATA
R410[ 98]
1U Rack
2009[ 99]
Intel 5500
2 LGA 1366
Xeon 5500 or 5600
128 GB
8, DDR3 800-1333
4 × 3.5″ or 4 × 2.5″
R415[ 100]
1U Rack
AMD SR5670 & SP5100
2 C32
Opteron 4100 , 4200 or 4300 [ 101]
256 GB[ 101]
8, DDR3 1066/1333
4 × 2.5″ or 4 × 3.5″ SAS or SATA
R510[ 102]
2U Rack
Intel 5500
2 LGA 1366
Xeon 5500 or 5600
128 GB
8, DDR3 800-1333
4 × 3.5″ or 8 × 2.5″/3.5″ or 12 × 2.5″/3.5″ and 2 × 2.5″ internal
R515[ 103]
2U Rack
2010
AMD SR5670 & SP5100
2 C32
Rev I: Opteron 4100 ; Rev II: 4100, 4200 or 4300
Opteron 4100: 128 GB; Opteron 4200/4300: 256 GB
8, DDR3 1333–1600
12 × 2.5″ or 8 × 3.5″
T610 (Gen I, II) [ 104]
Tower or 5U Rack
Intel 5520
2 LGA 1366
Xeon 5500 or 5600
192 GB
12, RDIMM or UDIMM DDR3 800-1333
Up to 8 × 3.5″/2.5″ SSD, SAS or SATA
R610 (Gen I, II) [ 105]
1U Rack
Intel 5520
2 LGA 1366
Xeon 5500 or 5600
192 GB
12, DDR3 800-1333
6 × 2.5″ SAS or SSD
M610 (Gen I, II) [ 106]
Blade
Intel 5520
2 LGA 1366
Xeon 5500 or 5600
192 GB
12, ECC DDR3
2 × 2.5″ SAS/SSD
Fits in the M1000E chassis
T710 (Gen I, II) [ 107]
Tower or 5U Rack
Intel 5520
2 LGA 1366
Xeon 5500 or 5600
288 GB
18, DDR3 800–1333
16 × 2.5″ or 8 × 3.5″
R710 (Gen I, II) [ 108]
2U Rack
2009[ 109]
Intel 5520
2 LGA 1366
Xeon 5500 or 5600
288 GB
18, DDR3 800-1333
8 × 2.5″ or 6 × 3.5″
Gen I: No 130 W CPUs
R715[ 110]
2U Rack
2010[ 111]
AMD SR5650, SR5670, SP5100
2 G34
Opteron 6100 or 6200
256 GB
16, DDR3 800–1600
8 × 2.5″ or 6 × 3.5″
M710 (Gen I, II) [ 112]
Blade
Intel 5520
2 LGA 1366
Xeon 5500 or 5600
192 GB
18, DDR3
4 × 2.5″ SAS or SSD
Fits in the M1000E chassis
R810 [ 113] [ 114]
2U Rack
Intel 7500
4 LGA 1567
Xeon 6500 or 7500
1 TB[ 115]
32, DDR3 1066
6 × 2.5″ SAS, SATA or SATA SSD
R815 [ 116] [ 117]
2U Rack
AMD SR5650, SR5670, SP5100
4 G34
Opteron 6100
1 TB
32, DDR3 1333
6 × 2.5″ SAS, SATA or SATA SSD
R910[ 118]
4U Rack
Intel 7500
4 LGA 1567
Xeon 7500 or E7-4/8800
2 TB[ 119]
64, DDR3 1066
16 × 2.5″ SAS or SSD
R910 servers using Xeon 7500 CPUs are limited to 1 TB of memory since 32 GB DIMMs are not supported[ 120]
M910[ 121]
Blade
Intel 7500
4 LGA 1567
Xeon 6500 or 7500
512 GB
32, ECC DDR3
2 × 2.5″ SAS or SSD
Fits in the M1000E chassis
C1100[ 122]
1U Rack
Intel 5500
2 LGA 1366
Xeon 5500 or 5600
192 GB
18, ECC DDR3 1066-1333
10 × 2.5″ or 4 × 3.5″
C2100[ 123]
2U Rack
Intel 5500
2 LGA 1366
Xeon 5500 or 5600
192 GB
18, ECC DDR3 1066-1333
12 × 3.5″ and 2 × 2.5″ internal SATA or SSD
C6100[ 124]
2U Rack
Intel 5520
8 LGA 1366
Xeon 5500 or 5600
768 GB
48, DDR3 1066-1333
24 × 2.5″ or 12 × 3.5″
Generation 12
In March 2012 Dell introduced their 12th generation servers based on Intel Xeon. There are two basic lines: 620 and 720.[ 125] On the 720 line, Dell currently offers two rack-model servers: the Poweredge R720[ 126] and the R720XD[ 127] — where the latter offers the option to extend the system to up to 26 internal disks.
The Poweredge 620 series offer models for rack, tower and a ½ height blade-server M620.[ 125] A ½ height blade means that you can fit up to 16 of those servers in one M1000e enclosure. The M520 and M620 can also be used in the new PowerEdge VRTX system. The new M420 is 1/4 height, so 32 fit in a M1000e chassis but does require a special full height holder that fits 4 M420's in one full-height (=double) slot.
For the Generation 12 server-line the out of band server-management system iDRAC received a new version: iDRAC 7 . iDRAC allows you to access the server-console via a separate Ethernet connection allowing you to get access to the server even when there is no (working) operating system or (normal) network connection available. It offers more or less the same functionality as a network-enabled KVM switch , but with some additional options.
An overview of the offered servers as per July 2012[ 125]
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Internal Storage (Max)
Drive bays
PCI(e) slots
On board network
R220[ 128]
1U Rack
C222
1 LGA 1150
Xeon E3-1200 v3
32 GB
4, DIMM DDR3, 1600 MHz
2 × 2.5″ or 2 × 3.5″
1: 1 - x16 FH/FL
Dual 1 GB
R320[ 129]
1U Rack
C602
1 LGA 1356
Xeon E5-2400 or E5-2400 v2 or E5-1400
192 GB
6, DIMM DDR3, 1600 MHz
16 TB
8 × 2.5″ or 4 × 3.5″
2: 1x16 FH/HL, 1x8 HH/HL
Broadcom Dual 1 GB
R420[ 130]
1U Rack
C602
2 LGA 1356
Xeon E5-2400 or E5-2400 v2
384 GB
12, DIMM DDR3, 1600 MHz
16 TB
8 × 2.5″ or 4 × 3.5″
2: 1x16 FH/HL, 1x16 HH/HL (with 2 cpu)
or 2: 1x16 FH/HL, 1x8 HH/HL (with 1 cpu)
Broadcom Dual 1 Gb
R520
2U Rack
C602
2 LGA 1356
Xeon E5-2400 or E5-2400 v2
384 GB
12, DIMM DDR3, 1600 MHz
32 TB
8 x 2.5″ or 8 x 3.5″
1x16x HH/HL at 16x, 1x16x FH/FL at 8x, 2x16 FH/HL at 8x(with 2 cpu)
Broadcom Dual 1 Gb
R620[ 131]
1U Rack
2012
C600
2 LGA 2011
Xeon E5-2600 or E5-2600 v2
1.5 TB
24, DIMM DDR3, 1600 MHz
10 TB
8 × 2.5″ or 4 × 3.5″ + 2 × PCIe SSD
or 10 × 2.5″
3: 2 - x16 FH/FL, 1 - x8 FH/FL or 2, 2 x x16
Broadcom or Intel 4× 1GBor 2× 10 GB
T620[ 132]
Tower rackable, 5U
2012
C600
2 LGA 2011
Xeon E5-2600 or E5-2600 v2
768 GB
24, DIMM DDR3, 1866Mhz
36 TB
8 × 3.5″ + 4 × PCIe SSD or 12 × 3.5″ or 16 × 2.5″ + 4 × PCIe SSD or 32 × 2.5″
7: 4 - x16 FH/FL, 2 - x8 FH/FL, 1 - x8 (x4bw) FH/FL
Intel Dual 1 GB
R720[ 126]
2U Rack
2012
C600
2 LGA 2011
Xeon E5-2600 or E5-2600 v2
1.5 TB
24, DIMM DDR3, 1600Mhz
25 TB
8 × 3.5″ or 16 × 2.5″
7: 1x16 FH/FL, 3x8 FH/FL, 3x8 HH/HL
Broadcom or Intel 4× 1GBor 2× 10 GB
R720XD[ 127]
2U Rack
2012
C600
2 LGA 2011
Xeon E5-2600 or E5-2600 v2
1.5 TB
24, DIMM DDR3, 1600Mhz
38 TB
26 × 2.5″ or 12 × 3.5″ + 2 × 2.5″
6: 2 - x16 FH/FL, 1 - x8 FH/FL, 3 - x8 HH/HL
Broadcom or Intel 4× 1GBor 2× 10 GB
R820[ 133]
2U Rack
2012
C600
4 LGA 2011
Xeon E5-4600
1.5 TB
48, DIMM DDR3 1600 MHz
16 TB
16 × 2.5″
7: 2 - x16 HL/FH, 1 - x8 HL/FH, 3 - x8 HL/HH, 1 - x8 HL/FH (for RAID controller)
Broadcom or Intel 4× 1GBor 2× 10 Gb
R920[ 134]
4U Rack
2012
C602J
4 LGA 2011
Xeon E7-2800/4800/8800 v2
6 TB
96, DIMM DDR3 1600 MHz
28.8 TB
24 × 2.5″
Broadcom or Intel 4× 1GBor 2× 10 Gb
M420[ 135]
Blade 1/4 height
2012
C600
2 LGA 1356
Xeon E5-2400
192 GB
6, DIMM DDR3, 1600Mhz
2 × 200 GB
2 × 1.8"
Broadcom [ b] 2× 10 Gb LOM +1 Mezzanine slot
M520[ 136]
Blade 1/2 height
2012
C600
2 LGA 1356
Xeon E5-2400
384 GB
12, DIMM DDR3, 1600Mhz
2 × SATA/SAS HDD/SSD
2 × 2.5″
Broadcom or Intel on board+2 Mezzanine slots
M620[ 137]
Blade 1/2 height
2012
C600
2 LGA 2011
Xeon E5-2600
768 GB
24, DIMM DDR3, 1600Mhz
2 × 2.5″
Broadcom or Intel on board+2 Mezzanine slots
M820[ 138]
Blade full height
2012
C600
4 LGA 2011
Xeon E5-4600
1.5 TB
48, DIMM DDR3, 1600 MHz
4 × SAS HDD/SSD or 2 × PCIe flash SSD
4 × 2.5″
2× 10 Gb Converged Ethernet Adaptor on board+2 Mezzanine slots
C6220 [ 139]
2U Rack
2012
C600
8 LGA 2011
Xeon E5-2600
2 TB
64, DIMM DDR3, 1600 MHz
48 TB
24 × 2.5″ or 12 × 3.5″
2× 1GBLOM, 100 Mb mgt + opt. InfiniBand Mezzanine
Other 12th Generation servers, which are comparable in capabilities with the above detailed M or R versions of the same model number , are:[ 140]
PE T320 Tower
PE T420 Tower
Generation 13
In September 2014 Dell introduced their 13th generation servers based on Intel Xeon
Model
Chassis
Year
Chipset
CPU (No.)
CPU (Type)
RAM (Max)
RAM (Type)
Internal Storage (Max)
Drive bays
PCI(e) 3.0 slots
On board network
T130[ 141]
Tower
2015
Intel C236
1
Xeon E3-1200 v6
64 GB
4, DDR4 up to 2400 MT/s
4 x 3.5” cabled HDD
1x8 PCIe 3.0 (x16 connector)
2x4 PCIe 3.0 (x8 connector)
1x1 PCIe 3.0 (x1 connector)
Broadcom 2x1Gb
R230[ 142]
1U Rack
2015
Intel C236
1
Xeon E3-1200 v5
64 GB
4, DDR4 up to 2133 MT/s
2 x 3.5” cabled HDD
4 x 3.5” cabled HDD
4 x 3.5” hot-swap or 2.5” hot-swap in hybrid drive carrier
2 x PCIe 3.0 slots
Broadcom 2x1Gb
T330
Tower
2015
Intel C236
1
Xeon E3-1200 v5
Xeon E3-1200 v6
64 GB
4, DDR4 up to 2133 MT/s [v5] 2400 MT/s [v6]
8 x 3.5” hot-swap
#1: PCIe 3.0 x4, x8 slot, CPU
#2: PCIe 3.0 x8, x16 slot, CPU
#3: PCIe 3.0 x1, x1 slot, PCH
#4: PCIe 3.0 x4, x8 slot, PCH
Broadcom 2x1Gb
R330[ 143] [ 144]
1U Rack
2015
Intel C236
1
Xeon E3-1200 v5 or Xeon E3-1200 v6 or Intel Core i3 6100 series or Intel Celeron G3900 series or Intel Celeron G3930 or Intel Pentium G4500 series or Intel Pentium G4600 series
64 GB
4, DDR4 up to 2133 MT/s
4 x 3.5” hot-swap
8 x 2.5” hot-swap
2 x PCIe 3.0 slots + 1 slot for internal storage
2 x 1 Gb
R430[ 145]
1U Rack
2014
Intel C610
1 / 2
Xeon E5-2600 v3 or Xeon E5-2600 v4 [ 146]
384 GB
12, DDR4 up to 2133 MT/s
20 TB (10 × 2.5″ SATA HDD)
18 TB (10 × 2.5″ SAS HDD)
10 x 2.5″ HDD: SAS, SATA, NL-SAS, SSD
8 x 2.5″ HDD: SAS, SATA, NL-SAS, SSD
4 × 3.5″ SAS, SATA, NL-SAS, SSD
2 × x8 HL/HH x16 (2 CPU)
2 x 1 Gb
4 × 1 Gb
2 × 1 GB+ 2 × 10 Gb
4 × 10 Gb
R530[ 147]
2U Rack
2014
Intel C610
1 / 2
Xeon E5-2600 v3
384 GB
12, DDR4, up to 2133 MT/s
32 TB (8 × 3.5″ SATA HDD)
14.4 TB (8 × 3.5″ SAS HDD)
8 x 3.5″ HDD: SAS, SATA, NL-SAS, SSD
3 × PCIe3.0 + 2 x PCIe2.0
2 x 1 Gb
4 × 1 Gb
2 × 1 GB+ 2 × 10 Gb
4 × 10 Gb
up to 8 x 10 GB+ 12 x 1GBusing PCI extension slot
R630[ 148]
1U Rack
2014[ 149]
Intel C610
2
Xeon E5-2600 v3 or Xeon E5-2600 v4
768 GB
24, DDR4 up to 2133 MT/s
23 TB (24 × 1.8″ SSD)
17 TB (10 × 2.5″ SAS HDD)
14 TB (8 × 2.5″ SAS HDD)
24 x 1.8″ SATA SSD
10 x 2.5″ HDD: SAS, SATA, NL-SAS, SSD, 4 NVMe PCIe
8 x 2.5″ HDD: SAS, SATA, NL-SAS, SSD
2 × x8 HL/HH x16 + 1 × HL/HH (x16 conn.) (2 CPU)
1 × x16 HL/HH x16 + 1 × .75L/FH (2 CPU)
1 × x16 HL/HH x8 (x16 conn.) + 1 × .75L/FH (1 CPU)
4 × 1 Gb
2 × 1 GB+ 2 × 10 Gb
4 × 10 Gb
T630[ 150]
Tower or 5U Rack
2014
Intel C610
2
Xeon E5-2600 v4
1.5 TB
24, DDR4 up to 2133 MT/s
144 TB (18 x 3.5″ HDD)
72 TB (32 x 2.5″ HDD)
4 Express Flash PCIe SSDs
8 × 3.5″ SAS, SATA, NL-SAS, SSD, PCIe SSD drives with optional flex bay
18 × 3.5″ SAS, SATA, NL-SAS, SSD drives
16 × 2.5″ SAS, SATA, NL-SAS, SSD, PCIe SSD drives with optional flex bay
32 × 2.5″ SAS, SATA, NL-SAS, SSD drives
4 × x16 FL/FH
2 × x8 FL/FH (PCIe 2.0)
1 × x8 HL/FH
1 × x8 HL/FH (PERC )
2 × Intel 1GBLOM
M630[ 151]
Blade 1/2 height
2014
Intel C610
2
Xeon E5-2600 v3
768 GB
24, DDR4 up to 2133 MT/s
4 × 1.8″ SSD
2 × 2.5″ PCIe SSD
2 × PCIe 3.0 (x8) mezzanine
(19 different optional adapters available)
R730[ 152]
2U Rack
2014
Intel C610
2
Xeon E5-2600 v3 or Xeon E5-2600 v4
1.5 TB
24, DDR4, up to 2133 MT/s
29 TB (16 × 2.5″ hot-plug SAS)
48 TB (8 × 3.5″ hot-plug NL SAS)
16 × 2.5″ SAS, SATA, NL-SAS, SSD
8 × 3.5″ SAS, SATA, NL-SAS, SSD
4 × 1 Gb
2 × 1 GB+ 2 × 10 Gb
4 × 10 Gb
R730xd[ 153]
2U Rack
2014
Intel C610
2
Xeon E5-2600 v3
768 GB
24, DDR4 up to 2133 MT/s
99.6 TB (12 × 3.5″ NL SAS HDD/SSD + 4 × 3.5″ SAS + 2 × 2.5″ SAS HDD/SSD)
68.5 TB (18 × 1.8″ SATA SSD + 8 × 3.5″ SAS HDD)
47.5 TB (24 × 2.5″ hot-plug SAS HDD + 2 × 2.5″ hot-plug SAS HDD)
16 × 3.5″ SAS, SATA, NL-SAS, SSD + 2 × 2.5″ drives
18 × 1.8″ SAS, SATA, NL-SAS, SSD drives + 8 × 3.5″ SAS, SATA, NL-SAS, SSD drives, + 2 × 2.5″ HDD
26 × 2.5″ SAS, SATA, NL-SAS, SSD, PCIe SSD drives
4 × 1 Gb
2 × 1 GB+ 2 × 10 Gb
4 × 10 Gb
R830
2U Rack
2016
Intel C612
4
Xeon E5-4600 v4
3 TB
24, DDR4 up to 2400 MT/s
61.4 TB (16 × 2.5″ SSD)
16 × 2.5″ SAS, SATA, NL-SAS, SSD drives
4 × 1 Gb
2 × 1 GB+ 2 × 10 Gb
4 × 10 Gb
FC830[ 154]
2U Rack
2016
Intel C612
4
Xeon E5-4600 v4
1.5 TB
48, DDR4 up to 2400 MT/s
16 × 1.8″ SSD or
8 × 2.5″ SSD
4-8 × PCIe 3.0 (x8)
1 × PERC
4 × 1 Gb
2 × 1 GB+ 2 × 10 Gb
4 × 10 Gb
R930[ 155]
4U Rack
2015
Intel C602J
4
Xeon E7-4800 v4
12 TB
DDR4 up to 2400 MT/s
Only with daughterboards
99.6 TB (12 × 3.5″ NL SAS HDD/SSD + 4 × 3.5″ SAS + 2 × 2.5″ SAS HDD/SSD)
68.5 TB (18 × 1.8″ SATA SSD + 8 × 3.5″ SAS HDD)
47.5 TB (24 × 2.5″ hot-plug SAS HDD + 2 × 2.5″ hot-plug SAS HDD)
16 × 3.5″ SAS, SATA, NL-SAS, SSD + 2 × 2.5″ drives
18 × 1.8″ SAS, SATA, NL-SAS, SSD drives + 8 × 3.5″ SAS, SATA, NL-SAS, SSD drives, + 2 × 2.5″ HDD
26 × 2.5″ SAS, SATA, NL-SAS, SSD, PCIe SSD drives
4 × 1 Gb
2 × 1 GB+ 2 × 10 GB
4 × 10 Gb
C4130[ 156]
1U Rack
2016
Intel C612
2
Xeon E5 2600 v4
1 TB
16, DDR4 up to 2400MT/s
Up to 4 × 2.5″ Drives with Tray
2 × PCIe 3.0 low profile Intel H OmniPath
Model
Chassis
Year
Chipset
CPU (No.)
CPU (Type)
RAM (Max)
RAM (Type)
Internal Storage (Max)
Drive bays
PCI(e) 3.0 slots
On board network
Generation 14
In July 2017 Dell EMC introduced their 14th generation servers, adding support for latest Intel Xeon Scalable Processors , better NVMe support and other updates.[ 157]
Model
Chassis
Year
Chipset
CPU (No.)
CPU (Type)
RAM (Max)
RAM (Type)
Internal storage (Max)
Drive bays
PCI(e) 3.0 slots
On board network
R240
1U Rack
2018
1
64 GB
4, DDR4 up to 2666 MT/s
4 x 3.5 SAS, SATA, or SSD
2 x 1 GbE LOM
R340
1U Rack
2018
Intel C246
1
Xeon E-2200 and E-2100 product family, Intel Core i3, Intel Pentium, Intel Celeron
64 GB
4, DDR4 up to 2666 MT/s
8 x 2.5 SAS, SATA, or SSD
4 x 3.5 SAS, SATA, or SSD
1 x16 slot PCIe Gen3 for HL/FH,
1 x 8 slot PCIe Gen3 for LP
2 x 1 GbE LOM
T340[ 158]
Tower or 5U Rack
2017
Intel C246
1
Xeon E-2200 and E-2100 product family, Intel Core i3, Intel Pentium, Intel Celeron
64 GB
4, DDR4 up to 2666 MT/s
8 x 3.5″ SAS/SATA (HDD/SSD)
8 x 2.5" SAS/SATA(HDD/SDD)(with hybrid drive Carrior)
1x8 Gen3 (x16 connector) FH/HL
1x8 Gen3 (x8 connector) FH/HL
1x4 Gen3 (x8 connector) FH/HL
1x1 Gen3 (x1 connector) FH/HL
2 X 1 GbE LOM
R440[ 159]
1U Rack
2017
2
XeonBronze 31xx or Silver 41xx or Gold 51xx, 61xx
1TB Max (768 GB max memory is recommended for performance optimized configurations)
16, DDR4 up to 2666 MT/s
64 TB (4 x 3.5″ hot-plug SAS/SATA HDD/SSD)
76.8 TB [ 160] (10 x 2.5″ hot-plug SAS/SATA HDD/SSD + 4 x NVMe SSD)
2 x M.2 SSD
4 x 3.5″ SAS, SATA, NL-SAS, SSD
8 x 2.5″ SAS, SATA, NL-SAS, SSD
10 x 2.5″ SAS, SATA, NL-SAS, SSD
10 x 2.5″ SAS, SATA, NL-SAS, SSD + 4 NVMe SSD
1 x PCIe 3.0 (FH/HL riser)
2 x PCIe 3.0 (HH/HL riser)
2 x 1 GbE LOM
2 x 10 GbE SFP+
2 x 10 GbE
T440[ 161]
Tower or 5U Rack
2017
2
XeonBronze 3[12]xx or Silver 4[12]xx or Gold 5[12]xx, up to 135 W
512 GB
16, DDR4 up to 2666MT/s
96 TB (8 x 3.5″ hot-plug SAS/SATA HDD/SSD)
61 TB (16 x 2.5″ hot-plug SAS/SATA HDD/SSD)
2 x M.2 SSD
4 x 3.5″ SAS, SATA, NL-SAS, SSD
8 x 3.5″ SAS, SATA, NL-SAS, SSD
16 x 2.5″ SAS, SATA, NL-SAS, SSD
5
2 x 1 Gb
T640[ 162]
Tower or 5U Rack
2017
Intel C620[ 163]
2
1st and 2nd Generation Intel Xeon Scalable, up to 205 W
3 TB
24, DDR4 up to 2666MT/s
216 TB
61 TB
122 TB
112 TB
8 or 18 x 3.5” SAS/SATA (HDD/SSD) max 216 TB
16 x 2.5” SAS/SATA (HDD/SSD) max 61 TB
32 x 2.5” SAS/SATA (HDD/SSD) max 122 TB
16 x 2.5 SAS/SATA (HDD/SSD) + 8 × NVMe SSD max 112 TB
Up to 8 PCIe Gen 3
2 x 10 Gb
R540[ 164]
2U Rack
2017
Intel C620[ 165]
2
Intel Xeon scalable
Bronze 31xx or Silver 41xx or Gold 51xx
or Gold 61xx
1 TB Max (768 GB max memory is recommended for performance optimized configurations)
16, DDR4 up to 2666 MT/s
Up to 12 x 3.5” SAS/SATA HDD max 168 TB
Up to 2 x 3.5 SAS/SATA HDD max 28 TB
Up to 6 PCIe[ 166]
2 x 1GGbE LOM
2 x 10 GbE SFP+
2 x 10 GbE
R640[ 167]
1U Rack
2017
Intel C620
2
1st and 2nd Generation Intel Xeon Scalable, up to 205 W
3 TB RDIMM, 7.68 TB DCPMM
24, DDR4 up to 2933 MT/s
max 76.8 TB
Front
up to 10 x 2.5” SAS/SATA (HDD/SSD) max 7.68 TB
up to 10 NVMe drives max 64 TB
up to 4 x 3.5” SAS/SATA, max 64 TB
Rear
Up to 2 x 2.5” SAS/SATA (HDD/SSD), NVMe SSD max 15.36 TB
3 (x16/x16/x16)
4 x 1 GbE
2 x 10 GbE + 2 x 1 GbE
4 x 10 GbE
2 x 25 GbE
R6415[ 168]
1U Rack
2017
1
1st Generation AMD Epyc
1 TB RDIMM
16, DDR4 up to 2666MT/s
max 76.8 TB
Front
up to 10 x 2.5” SAS/SATA (HDD/SSD)
up to 10 NVMe drives
up to 4 x 3.5” SAS/SATA
2 (x16/x16)
2 x 1 Gb Base-T
2 x 10Gb Base-T
2 x 10Gb SPF+
2 x 25Gb SPF+
R740[ 169]
2U Rack
2017
Intel C620
2
1st and 2nd Generation Intel Xeon Scalable, up to 205 W
3 TB RDIMM, 7.68 TB DCPMM
24, DDR4 up to 2933 MT/s
Up to 16 x 2.5″ SAS/SATA
8 x 3.5" SAS/SATA
4 x 1 GbE
2 x 10 GbE + 2 x 1 GbE
4 x 10 GbE
2 x 25 GbE
R740XD[ 170]
2U Rack
2017
Intel C620
2
Intel Xeon scalable
3 TB
24, DDR4 up to 2666 MT/s
Front: NVMe SSD max 153 TB or SAS/SATA HDD max 144 TB
Mid Bay: max 48 TB
Rear: max 25 TB
Front: 12 x 3.5" SAS/SATA
Front: 24 x 2.5” SAS/SATA
Rear: Up to 2 x 3.5” SAS/SATA
Rear: Up to 4 x 2.5″ SAS/SATA
4 x 1 GbE
2 x 10 GbE + 2 x 1 GbE
4 x 10 GbE
2 x 25 GbE
R940[ 171]
3U Rack
2017
4
Intel Xeon Gold/Platinum
6 TB
48, DDR4 up to 2666 MT/s
184.32 TB max
24 x 2.5” SAS/SATA (HDD/SSD)
4 × 1 GbE
4 × 10 GbE
2 × 10 GbE + 2 × 1 GbE
2 × 25 GbE
M640
Blade 1/2 height
2
2nd Generation Xeon Scalable
2 TB
16, DDR4 up to 2933 MT/s
12.8 TB max
2 x 2.5” SAS/SATA (HDD/SSD)
2 × 10 GbE + 4 × 1 GbE
4 × 10 GbE
FC640[ 172]
1U
2019
2
2nd Generation Xeon Scalable
2 TB
16, DDR4 up to 2933 MT/s
12.8 TB
2 x 2.5” SAS/SATA (HDD/SDD)
2 x 10 GbE + 2 x 1 GbE
4 x 10 GbE
C6420[ 173]
2U Rack
2017
Model
Chassis
Year
Chipset
CPU (No.)
CPU (Type)
RAM (Max)
RAM (Type)
Internal storage (Max)
Drive bays
PCI(e) 3.0 slots
On board network
Generation 15
On March 17, 2021, Dell officially launched their 15th generation PowerEdge servers[ 174] with some models already available in 2019.
Model
Chassis
Year
Chipset
CPU (No.)
CPU (Type)
RAM (Max)
RAM (Type)
Internal storage (Max)
Drive bays
PCIe 3.0/4.0 slots
On board network
R6515
1U Rack
2019
SoC
1
2nd and 3rd generation AMD EPYC
2 TB
16, DDR4-3200, 8 channels
32 TB
4 × 3.5″ (LFF)
8 × 2.5″ (SFF)
0–2
2× 1GE
2× 10GE SFP+
2× 25GE SFP28
R6525
1U Rack
2019
SoC
2
2nd and 3rd generation AMD EPYC
4 TB
32, DDR4-3200, 16 channels
32 TB
4 × 3.5″ (LFF)
8 × 2.5″ (SFF)
0–2
2× 1GE
2× 10GE SFP+
2× 25GE SFP28
R7515
2U Rack
2019
SoC
1
2nd and 3rd generation AMD EPYC
2 TB
16, DDR4-3200, 8 channels
112 TB
8–14 × 3.5″ (LFF)
24 × 2.5″ (SFF)
0–4
2× 1GE
2× 10GE SFP+
2× 25GE SFP28
R7525
2U Rack
2019
SoC
2
2nd and 3rd generation AMD EPYC
4 TB
32, DDR4-3200, 16 channels
112 TB
8–12 × 3.5″ (LFF)
26 × 2.5″ (SFF)
0–8
2× 1GE
2× 10GE SFP+
2× 25GE SFP28
R750
2U Rack
May 2021
SoC
2
3rd generation Intel Xeon Scalable(up to 40 cores per processor)
RDIMM 2 TB
or LRDIMM 8 TB
32, DDR4-3200, 16 channels
0–8
R250
1U Rack
November 2021
FCLGA1200
1
Intel Xeon series E-2300 or Intel Pentium
128 GB
32, DDR4-3200 (DDR4-2666Mhz for Intel Pentium Processor), 4 channels
0-2
2× 1GE
Ability to add a network card
R350
1U Rack
November 2021
FCLGA1200
1
Intel Xeon series E-2300 or Intel Pentium
128 GB
32, DDR4-3200 (DDR4-2666Mhz for Intel Pentium Processor), 4 channels
0-3
2× 1GE
Ability to add a network card
R450
1U Rack
2021
FCLGA4189
2
3rd generation Intel Xeon Scalable (Up to 24 cores per processor)
1 TB
64, DDR4-2933, 16 channels
1-2
2× 1GE
Ability to add a network card
R550
2U Rack
2021
FCLGA4189
2
3rd generation Intel Xeon Scalable (Up to 24 cores per processor)
1 TB
64, DDR4-2933, 16 channels
128 TB
61,44 TB
122,88 TB
8 × 3.5″
8 × 2.5″
16 × 2.5″
1-3
2× 1GE
Ability to add a network card
C6525[ 175]
Blade 1/2 width
2019
SoC
2
2nd and 3rd generation AMD EPYC
2 TB
16, DDR4-3200, 8 channels
6 × 2.5" (SFF)
2 × M.2 SATA via BOSS riser card
0–2
XE8545[ 176]
4U Rack
2021
SoC
2
3rd generation AMD EPYC
4 TB
32, DDR4-3200, 16 channels
10 × 2.5″ (SFF SAS/SATA)
Up to 8 × 2.5″ (SFF NVMe)
0–4
2× 1GE
2× 10GE SFP+
2× 25GE SFP28
Model
Chassis
Year
Chipset
CPU (No.)
CPU (Type)
RAM (Max)
RAM (Type)
Internal storage (Max)
Drive bays
PCIe 3.0/4.0 slots
On board network
Generation 16
This section
needs expansion . You can help by
adding to it .
(May 2024 )
Dell officially launched their 16th generation PowerEdge servers[ 177] in the first half of 2023.
Model
Chassis
Year
Chipset
CPU (No.)
CPU (Type)
RAM (Max)
RAM (Type)
Internal storage (Max)
Drive bays
PCIe 4.0/5.0 slots
On board network
R260
1U Rack
2024
1
Intel® Xeon® E Processor
128 GB
32GB UDIMM, 5600MT/s ECC
6 x 2.5" SAS/SATA (46.08TB)
2 x 1 GbE
R360
1U Rack
2024
1
1 x Intel® Xeon® E-series processor
128 GB
32GB UDIMM, 5600MT/s ECC
4 x 3.5" SAS/SATA (64 TB)
2 x 1 GbE
R760
2U Rack
2023
Intel C741
2
4th and 5th
Generation
Intel Xeon
Scalable(Up 56 to cores per Processor for 4th Gen
and Up to 64 Cores for 5th Gen
8 TB
32, DDR5 DIMM
8TB RDIMM
Generation 17
Model
Chassis
Year
Chipset
CPU (No.)
CPU (Type)
RAM (Max)
Ram (Type)
Internal storage (Max)
Drive bays
PCIe 4.0/5.0 slots
On board network
R470
1U Rack
2024
1
One Intel Xeon 6 processor with up to 144 cores per processor
1 TB
16 DDR5 DIMM
122.4TB with E3.S
122.4TB with NVMe SSD
8 EDSFF
8 x 2.5 inch NVMe/SAS/SATA
0-2
OCP NIC card 3.0
R570
2U Rack
2024
1
one Intel® Xeon® 6 6700/6500 processor (E-core or P-core)
1.5 TB
96 DDR5 DIMM
288 TB
12 x 3.5-inch SAS (HDD)
-
R670
1U Rack
2024
2
Two Intel Xeon 6 Processors with up to 144 cores per processor
2 TB
32 DDR5 DIMM
122.4TB with E3.S
245.6TB with NVMe SSD
8 EDSFF
8 x 2.5 inch NVMe/SAS/SATA
0-2
OCP NIC card 3.0
R770
2U Rack
2024
2
Two Intel Xeon 6 Processor with up to 144 cores per processor
2 TB
32 DDR5 DIMM
244.8TB with E3.S
245.6TB with NVMe SSD
8 or 16 EDSFF
8 or 16 NVMe/SAS/SATA
0-4
OCP NIC card 3.0
PowerEdge SC Value Servers
Independent from the main generations of servers a value line was produced.
Model
Chassis
Year
Chipset
CPU (No. & Socket)
CPU (Type)
RAM (Max)
RAM (Type)
Drive bays
Comments
300 SC[ 178]
Tower
Intel 440BX
Pentium III
1 GB
4, ECC reg PC-100
1400 SC[ 179]
Tower
2000
2
Pentium III
2 GB
4, ECC reg PC-133
Ultra3 SCSI controller
500 SC[ 180]
Tower
2001[ 181]
ServerWorks ServerSet LE 3.0
1
Pentium III 1.0+ or Celeron 800Mhz+
2 GB
4, ECC PC-133
1500 SC[ 182]
Tower
2
Pentium III 1.1 GHz
4 GB
4, ECC reg PC-133
6 hot-swappable Ultra3 SCSI HDD bays
600 SC[ 183]
Tower
2003
ServerWorks GC-SL
1
Pentium 4 2.0+ or Celeron 1.7+
4 GB
4, ECC DDR 200
1600 SC[ 184]
Tower
2004
ServerWorks GC-SL
2
Xeon at up to 3.2 GHz
4 GB
4, ECC DDR 266
420 SC[ 185]
Tower
2004
Intel E7221
1
Pentium 4 or Celeron
4 GB
4, ECC DDR2 400–533
1420 SC[ 186]
Tower
2004
Intel E7520
2 Socket 604
Xeon, 800Mhz FSB
8 GB
6, ECC DDR2-400
(3) internal 3.5″ (2) 5.25 external up to 4 HDD
1425 SC[ 187]
1U Rack
Intel E7520
2
Xeon, 800Mhz FSB
12 GB
6, ECC DDR2 400
up to 4 HDD
430 SC[ 188]
Tower
2005
Intel E7230
1 LGA 775
Pentium 4 or Celeron D
4 GB
4, ECC DDR2 533
(2) ext. 5.25″ (1) ext. 3.5″ (2) int. 3.5″
1430 SC[ 189]
Tower
2006
Intel 5000V
2 LGA 771
Xeon 5300, Xeon 5100, Xeon 5000
16 GB
4, ECC DDR2 533-667 MHz
4 3.5″ SAS or SATA
1435 SC[ 190]
1U Rack
2007
Broadcom HT-2100 and HT-1000
2 Socket F
Opteron 2200 or 2300
32 GB
8, ECC DDR2 667
1 slimline bay
440 SC[ 191]
Tower
2006
Intel 3000 MCH
1 LGA 775
Xeon 3000, Pentium D or Celeron D
8 GB
4, ECC DDR2 533–667
(2) ext. 5.25″ (1) ext. 3.5″ (2) int. 3.5″
Although Dell's literature says the max RAM is 4 GB, several people have had success running it with 8 GB RAM total
Notes
References
^ a b Serverwatch website Spotlight on Dell Archived 2012-03-24 at the Wayback Machine , 15 May 2008, visited 28 June 2011
^ "How to identify a Dell PowerEdge server generation | Dell US" .
^ Infoworld website Dell revamps Poweredge line , 12 November 2007, visited 28 June 2011
^ Dornbusch, Margaret (May 1, 1995). "Bevy of new servers spring up". Network World . 12 (18). Framingham, Massachusetts : IDG Network World: 23. ISSN 0887-7661 .
^ "Benchmark Tests: File Servers". PC Magazine . 13 (17). Ziff Davis, Inc.: 218 October 11, 1994. Benchmark Tests: File Servers
^ a b c d e f Dell PowerEdge SP 5100-2/5133-2/5166-2 manual
^ a b DeVoe, Deborah (November 20, 1995). "Dell joins Internet parade with Web server". InfoWorld . 17 (47). San Francisco, California : InfoWorld Media Group: 6. ISSN 0199-6649 .
^ Dell PowerEdge XL 5133-4 manual
^ Dell PowerEdge 2100 Service Manual Archived 2012-03-13 at the Wayback Machine
^ Dell PowerEdge 4100 User Guide Archived 2010-08-27 at the Wayback Machine
^ Dell PowerEdge 6100 User Guide Archived 2012-03-13 at the Wayback Machine
^ Dell PowerEdge 2200 User Guide Archived 2012-03-13 at the Wayback Machine
^ Dell PowerEdge 4200 Specifications Archived 2010-11-17 at the Wayback Machine
^ Dell PowerEdge 350 Technical Specification Archived 2012-01-05 at the Wayback Machine
^ Dell PowerEdge 1300 Technical Specifications
^ Dell PowerEdge 2300 Technical Specifications Archived 2012-03-28 at the Wayback Machine
^ Dell PowerEdge 4300 Technical Specifications Archived 2012-03-28 at the Wayback Machine
^ Dell PowerEdge 4350 User Guide Archived 2012-03-28 at the Wayback Machine
^ Dell PowerEdge 6300 Technical Specifications Archived 2012-03-28 at the Wayback Machine
^ Dell PowerEdge 6350 Technical Specifications Archived 2012-03-28 at the Wayback Machine
^ Dell PowerEdge 2400 Technical Specifications Archived 2011-01-03 at the Wayback Machine
^ PC Pro review of the Dell PowerEdge 2400
^ Dell PowerEdge 2450 Technical Specifications Archived 2012-03-28 at the Wayback Machine
^ Dell PowerEdge 4400 Technical Specifications Archived 2011-06-23 at the Wayback Machine
^ Dell PowerEdge 6400 Technical Specifications Archived 2012-03-11 at the Wayback Machine
^ Dell PowerEdge 6450 Technical Specifications Archived 2012-03-28 at the Wayback Machine
^ Dell PowerEdge 8450 Technical Specifications
^ Novell, Dell PowerEdge 8450 Netwear test report
^ Dell PowerEdge 1500SC Technical Specifications Archived 2024-06-23 at the Wayback Machine
^ Dell PowerEdge 1550 Technical Specifications Archived 2012-03-28 at the Wayback Machine
^ PC Pro review of the Dell PowerEdge 1550 Archived 2010-11-18 at the Wayback Machine
^ Dell PowerEdge 2500 Technical Specifications Archived 2010-10-09 at the Wayback Machine
^ Dell PowerEdge 2550 Technical Specifications Archived 2012-01-11 at the Wayback Machine
^ Dell PowerEdge 3250 Specification Sheet
^ Dell PowerEdge 7150 Technical Specifications Archived 2010-04-12 at the Wayback Machine
^ PC Pro review of the Dell PowerEdge 7150
^ Dell PowerEdge 7250 Specification Sheet
^ Dell PowerEdge 650 Specification Sheet
^ Dell PowerEdge 1650 Technical Specifications
^ Novell, Dell PowerEdge 1650 Netware test report
^ Dell PowerEdge 1655MC Specification Sheet
^ Dell PowerEdge 2600 Specification Sheet
^ Dell PowerEdge 2650 Specification Sheet
^ Dell PowerEdge 4600 Specification Sheet
^ a b Dell PowerEdge 66X0 Specification Sheet
^ Dell PowerEdge 700 Specification Sheet
^ Dell PowerEdge 750 Specification Sheet
^ Dell PowerEdge 1750 Specification Sheet
^ Dell PowerEdge 800 Specification Sheet
^ Dell PowerEdge 830 Specification Sheet
^ Dell PowerEdge 840 Specification Sheet
^ PowerEdge 840 A08 BIOS Release Notes
^ Dell PowerEdge 1800 Technical Specifications
^ Dell PowerEdge 1850 Specification Sheet
^ Dell PowerEdge 1855 Specification Sheet
^ Dell PowerEdge 2800 Specification Sheet
^ Dell PowerEdge 2850 Specification Sheet
^ Dell PowerEdge 6800 Specification Sheet
^ Dell PowerEdge 6850 Specification Sheet
^ Dell PowerEdge 850 Info brief
^ Dell PowerEdge 860 Specification Sheet
^ PowerEdge 860 A05 BIOS Release Notes
^ Dell PowerEdge 1900 Specification Sheet
^ Dell PowerEdge 1950 Specification Sheet
^ Dell PowerEdge 1955 Specification Sheet
^ Dell PowerEdge 2900 Specification Sheet
^ Dell PowerEdge 2950 Specification Sheet
^ Dell PowerEdge 2950 III Specification Sheet
^ Dell PowerEdge 1950/2950 Memory Capacity
^ Dell PowerEdge 2970 Specification Sheet
^ PC Pro Review of the Dell Power PowerEdge 2970
^ Dell PowerEdge 6950 Specification Sheet
^ PC Pro Review of the Dell Power PowerEdge 6950
^ Dell PowerEdge T100 Specification Sheet
^ PC Pro review of Dell PowerEdge T100
^ Dell PowerEdge T105 Specification Sheet
^ Dell PowerEdge R200 Specification Sheet
^ Dell PowerEdge T300 Specification Sheet
^ Dell PowerEdge R300 Specification Sheet
^ Dell PowerEdge M600 Blade Server
^ Dell PowerEdge T605 Specification Sheet
^ PC Pro review of Dell PowerEdge T605
^ Dell PowerEdge M605/E1000E Specification Sheet
^ Dell PowerEdge R805 Specification Sheet
^ PC Pro review of Dell PowerEdge R805
^ Dell PowerEdge M805 Specification Sheet
^ Dell PowerEdge R900 Specification Sheet
^ Dell PowerEdge R905 Specification Sheet
^ Dell PowerEdge M905 Specification Sheet
^ Dell PowerEdge T110 Specification Sheet
^ Dell PowerEdge T110 II Specification Sheet
^ Dell PowerEdge R210 Specification Sheet
^ Dell PowerEdge R210 II Specification Sheet
^ Dell PowerEdge T310 Specification Sheet
^ Dell PowerEdge R310 Specification Sheet
^ Dell PowerEdge T410 Specification Sheet
^ PC Pro review of Dell PowerEdge T410
^ Dell PowerEdge R410 Specification Sheet
^ PC Pro review of Dell PowerEdge R410
^ Dell PowerEdge R415 Specification Sheet
^ a b "Memory Information for 11th Generation AMD Processor Servers | Dell New Zealand" .
^ Dell PowerEdge R510 Specification Sheet
^ Dell PowerEdge R515 Specification Sheet
^ Dell PowerEdge T610 Specification Sheet
^ Dell PowerEdge R610 Specification Sheet
^ Dell PowerEdge M610 Specification Sheet
^ Dell PowerEdge T710 Specification Sheet
^ Dell PowerEdge R710 Specification Sheet
^ PC Pro review of Dell PowerEdge R710
^ Dell PowerEdge R715 Specification Sheet
^ PC Pro review of Dell PowerEdge R715
^ Dell PowerEdge M710 Specification Sheet
^ Dell PowerEdge R810 Specification Sheet
^ Stevens, Alan (June 25, 2010). "Dell PowerEdge R810" . ZDNet . Retrieved March 7, 2012 .
^ Dell PowerEdge R810 System Memory Update
^ Dell PowerEdge R815 Specification Sheet
^ Dignan, Larry (March 30, 2010). "Dell PowerEdge R815" . ZDNet . Retrieved April 13, 2012 .
^ Dell PowerEdge R910 Specification Sheet
^ "dell R910 spec" (PDF) .
^ Intel® Xeon® Processor 7500 Series Datasheet, Volume 2
^ Dell PowerEdge M910 Specification Sheet
^ Dell PowerEdge C1100 Specification Sheet
^ Dell PowerEdge C2100 Specification Sheet
^ Dell PowerEdge C6100 Specification Sheet
^ a b c Overview page about the Poweredge 12th generation servers , visited 7 March 2012
^ a b "Dell PowerEdge R720 Spec Sheet" (PDF) . Dell . Retrieved October 9, 2019 .
^ a b "Dell PowerEdge R720XD Spec Sheet" (PDF) . Dell . Retrieved October 9, 2019 .
^ Dell website: Poweredge R220 Technical specifications , visited 2 October 2014
^ Dell website: Poweredge R320 Technical specifications , visited 24 March 2016
^ Dell website: Poweredge R420 Technical specifications , visited 2 October 2014
^ Dell website: Poweredge [1] , visited 7 March 2012
^ "Dell PowerEdge T620 Technical Guide" (PDF) . Dell . Retrieved January 10, 2024 .
^ Dell website: Poweredge PowerEdge R820 rack server details , visited 06 February 2012
^ Dell website: Poweredge PowerEdge R920 rack server details , visited 05 May 2019
^ Dell website: Poweredge M420 Technical specifications , visited 17 July 2012
^ Dell website: Poweredge M520 Technical specifications , visited 28 July 2012
^ Dell website: Poweredge M620 Technical specifications , visited 7 March 2012
^ Dell website: Poweredge M820 Technical specifications , visited 28 July 2012
^ Dell website: Poweredge C6220 Technical specifications , visited 28 July 2012
^ Overview 12th Generation servers , Dell website. Visited 28 July 2012
^ Dell PowerEdge T130 Specification Sheet
^ Dell PowerEdge R230 Specification Sheet
^ Dell PowerEdge R330 Specification Sheet
^ Dell PowerEdge R330 Owner's Manual
^ Dell PowerEdge R430 Specification Sheet
^ Dell-PowerEdge-R430-Spec-Sheet.pdf Archived November 22, 2023
^ Dell PowerEdge R530 Specification Sheet
^ Dell PowerEdge R630 Specification Sheet
^ Dell 13th Generation PowerEdge Server Resources , Dell website. Visited 17 February 2015
^ Dell PowerEdge T630 Specification Sheet
^ "Dell PowerEdge M630 Specification Sheet" (PDF) . i.dell.com . Retrieved 1 March 2020 .
^ Dell PowerEdge R730 Specification Sheet
^ Dell PowerEdge R730xd Specification Sheet
^ "Dell PowerEdge FC830 SpecSheet" (PDF) . dell.com .
^ Dell PowerEdge R930 Specification Sheet
^ Dell EMC PowerEdge C4130 Specification Sheet
^ Press Release about 14th generation
^ Dell EMC PowerEdge T430 Tech Sheet
^ Dell EMC PowerEdge R440 Specification Sheet
^ "Dell PowerEdge R440 Server" . Server Basket . 20 September 2021.
^ Dell EMC PowerEdge T440 Specification Sheet
^ "Dell EMC PowerEdge T640 Specification Sheet" (PDF) .
^ "Dell EMC PowerEdge T640. Technical Guide" (PDF) .
^ "Dell PowerEdge R540 Server Specifications 2019" (PDF) . Dell.com .
^ "Dell EMC PowerEdge R540 System. Technical Guide" (PDF) .
^ "Dell EMC PowerEdge R540 Server Overview" (PDF) . Dell.com .
^ Dell EMC PowerEdge R640 Technical Guide
^ Dell EMC PowerEdge R6415 Owner's Manual
^ Dell EMC PowerEdge R740 Specification Sheet
^ Dell EMC PowerEdge R740XD Specification Sheet
^ Dell EMC PowerEdge R940 Specification Sheet
^ Dell EMC PowerEdge FC640 Specification Sheet
^ Dell EMC PowerEdge C6420 Specification Sheet
^ "Dell Technologies Powers AI and Edge Computing with Next Generation PowerEdge Servers" . 2021-03-17. Retrieved 2021-03-24 .
^ Dell PowerEdge C6525 Technical Specifications
^ Dell PowerEdge XE8545 Technical Specifications
^ "Next-Generation Dell PowerEdge Servers Deliver Advanced Performance and Energy Efficient Design" . 2023-01-17. Retrieved 2023-05-01 .
^ Dell PowerEdge 300 Technical Specification Archived 2012-03-28 at the Wayback Machine
^ Dell PowerEdge 1400SC Technical Specifications Archived 2012-03-28 at the Wayback Machine
^ Dell PowerEdge 500SC Technical Specification
^ PC Mag review of the Dell PowerEdge 500SC
^ Dell PowerEdge 1500SC Technical Specifications
^ Dell PowerEdge 600SC Specification Sheet
^ Dell PowerEdge 1600SC Specification Sheet
^ Dell PowerEdge SC420 Specification Sheet
^ Dell PowerEdge SC1420 Specification Sheet
^ Dell PowerEdge SC1425 Technical Specifications
^ Dell PowerEdge SC430 Specification Sheet
^ Dell PowerEdge SC1430 Specification Sheet
^ Dell PowerEdge SC1435 Specification Sheet
^ Dell PowerEdge SC440 Specification Sheet
External links